Hollow bore (blind) encoder,
Resolution: up to 16384 ppr,
Housing: Ø 36 mm
Hollow bore blind: Ø 6 mm, Ø 1/4" (6.35 mm),
Signal shape: square-wave,
Selectable: Set zero pulse,
TTL/RS422 output possible at 10-32 VDC,
Operating principle: magnetic.

- Due to high quality electronics any number of pulses up to 16384
- Protection class IP67, at shaft input IP65
- High output frequency up to 1 MHz
- Reverse polarity protection and short-circuit protection at 4.75 VDC to 32 VDC
Insertion depth min.: 8 mm
Insertion depth max.: 17 mm
Max. Permissible shaft loading radial: 80 N
Max. Permissible shaft loading axial: 50 N
Insertion depth min.: 8 mm
Insertion depth max.: 17 mm
Max. Permissible shaft loading radial: 80 N
Max. Permissible shaft loading axial: 50 N
Current consumption: typ. 80 mA
Set zero pulse:
Set: SET = +UB for 2 s
Deaktivate: SET = GND
Environmental data
ESD (DIN EN 61000-4-2):
8 kV
Burst (DIN EN 61000-4-4):
2 kV
includes EMC:
DIN EN 61000-6-2
DIN EN 61000-6-3
Vibration:
(DIN EN 60068-2-6)
50 m/s2 (10 Hz up to 2000 Hz)
Shock:
(DIN EN 60068-2-27)
1000 m/s2 (6 ms)
Design:
According DIN VDE 0160
Duty information
Customs tariff number:
90318020
Country of origin:
Germany
Description | ABN inv. poss. | |
---|---|---|
L2 | axial, shield connected to encoder housing | ● |
L2 | L2 | L2 | L2 | |
Circuit | M11, M12 | M13, M14 | N11, N12 | N13, N14 |
GND | WH | WH | WH | WH |
(+) Vcc | BN | BN | BN | BN |
A | GN | GN | GN | GN |
B | YE | YE | YE | YE |
N | GY | GY | GY | GY |
SET | - | PK | - | PK |
A inv. | RD | RD | - | - |
B inv. | BK | BK | - | - |
N inv. | VT | VT | - | - |
Shield | flex | flex | flex | flex |
Description | ABN inv. poss. | |
---|---|---|
L3 | radial, shield connected to encoder housing | ● |
L3 | L3 | L3 | L3 | |
Circuit | M11, M12 | M13, M14 | N11, N12 | N13, N14 |
GND | WH | WH | WH | WH |
(+) Vcc | BN | BN | BN | BN |
A | GN | GN | GN | GN |
B | YE | YE | YE | YE |
N | GY | GY | GY | GY |
SET | - | PK | - | PK |
A inv. | RD | RD | - | - |
B inv. | BK | BK | - | - |
N inv. | VT | VT | - | - |
Shield | flex | flex | flex | flex |
Description | ABN inv. poss. | |
---|---|---|
K1 | radial, shield not connected (IP40) | ● |
K1 | K1 | K1 | K1 | |
Circuit | M11, M12 | M13, M14 | N11, N12 | N13, N14 |
GND | WH | WH | WH | WH |
(+) Vcc | BN | BN | BN | BN |
A | GN | GN | GN | GN |
B | YE | YE | YE | YE |
N | GY | GY | GY | GY |
SET | - | PK | - | PK |
A inv. | RD | RD | - | - |
B inv. | BK | BK | - | - |
N inv. | VT | VT | - | - |
Shield | flex | flex | flex | flex |
Description | ABN inv. poss. | |
---|---|---|
SB5 | axial, 5-pin, Connector connected to encoder housing | - |
SB8 | axial, 8-pin, Connector connected to encoder housing | ● |
SB12 | axial, 12-pin, Connector connected to encoder housing | ● |
Description | ABN inv. poss. | |
---|---|---|
SC5 | radial, 5-pin, Connector connected to encoder housing | - |
SC8 | radial, 8-pin, Connector connected to encoder housing | ● |
SC12 | radial, 12-pin, Connector connected to encoder housing | ● |
1-16384 PPR
The WDGP 36E shaft encoder is also optionally available with a pressure equalising membrane. This prevents water from penetrating into the encoder housing in the case of high air humidity.
The IP67 protection level, temperature range and salt spray resistance are maintained. Resistant to chemicals and solvents in accordance with DIN EN ISO 2812-1.
Please extend the standard order code with a three figure number, specifying the cable length in decimetres.
Example: 5 m cable = 050

Female connector KI-5-67:
Suitable for encoder with sensor connector outlet SB5 and SC5, 5 pin, IP67
Ready-made shielded connection cable with female cable connector straight,
shield connected.

Female connector KIA-5-67:
Suitable for encoder with sensor connector outlet SB5 and SC5, 5 pin, IP67
Ready-made shielded connection cable with female cable connector angular,
shield connected.

Female connector KI-8-67:
Suitable for encoder with sensor connector outlet SB8 and SC8, 8 pin, IP67
Ready-made shielded connection cable with female cable connector straight,
shield connected.

Female connector KIA-8-67:
Suitable for encoder with sensor connector outlet SB8 and SC8, 8 pin, IP67
Ready-made shielded connection cable with female cable connector angular,
shield connected.

Female connector KI-12-67:
Suitable for encoder with sensor connector outlet SB12 and SC12, 12 pin, IP67
Ready-made shielded connection cable with female cable connector straight,
shield connected.

Female connector KIA-12-67:
Suitable for encoder with sensor connector outlet SB12 and SC12, 12 pin, IP67
Ready-made shielded connection cable with female cable connector angular,
shield connected.

Torque support WDGDS10016
for hollow shaft encoder 36E with hollow shaft (blind) Ø 6 mm.

Shaft adapter WDGWA10M06
for thru-bore and hollow bore (blind) encoder Ø 10 mm
or couplings Ø 10 mm,
thread M6.

Shaft adapter WDGWA10M08
for thru-bore and hollow bore (blind) encoder Ø 10 mm
or couplings Ø 10 mm,
thread M8.

Shaft adapter WDGWA10M10
for thru-bore and hollow bore (blind) encoder Ø 10 mm
or couplings Ø 10 mm,
thread M10.

Shaft adapter WDGWA10M12
for thru-bore and hollow bore (blind) encoder Ø 10 mm
or couplings Ø 10 mm,
thread M12.
STEP file: WDGWA10M12.stp

Shaft adapter WDGWA10M14
for thru-bore and hollow bore (blind) encoder Ø 10 mm
or couplings Ø 10 mm,
thread M14.

Shaft adapter WDGWA10M16
for thru-bore and hollow bore (blind) encoder Ø 10 mm
or couplings Ø 10 mm,
thread M16.
STEP file: WDGWA10M16.stp

Shaft adapter WDGWA10M20
for thru-bore and hollow bore (blind) encoder Ø 10 mm
or couplings Ø 10 mm,
thread M20.
Here you find a list of our distributors worldwide