deenfresitcntr
WDG 58V

Shaft Encoder incremental, optical,
Resolution: up to 25000 ppr,
Clamping flange: Ø 58 mm

Especially for food and beverage industry
Acid- and alkaline resistance

Shaft: Ø 10 mm,
Protection rating: IP67 + IP69K,
Signal shape: square-wave or sine/cosine.

Data sheetGeneral technical data incremental encoders (PDF 855 kB)
Drehgeber WDG58V
Highlights
  • EHEDG: Tested hygienic design
  • Resistance to Salt mist acc. (IEC 60068-2-11)
  • Up to 25000 PPR by use of high grad electronics
  • Ecolab: Certificate on resistance to cleaning and disinfection agents
  • High protection rating IP67 all around and IP69K
    (high pressure / steam cleaning)
  • Radial shaft sealing ring with no dead-room (PTFE)
  • Full connection protection with 10 VDC up to 30 VDC
  • With light reserve warning
Product details
Flange
clamping flange
Pulses per revolution PPR
up to 25000 PPR
Housing
Ø 58 mm
stainless steel, V4A
Shaft
Ø 10 mm
Shaft length: L: 18 mm
Max. Permissible shaft loading radial: 100 N
Max. Permissible shaft loading axial: 100 N
Max. operating speed
3600 rpm
Output circuit
TTL
TTL, RS422 compatible, inv.
HTL
HTL, inv.
1 Vpp sin/cos
Output frequency
TTL ≤ 5000 ppr, max. 200 kHz
HTL ≤ 5000 ppr, max. 200 kHz
TTL more than 1200 ppr, max. 2 MHz
HTL more than 1200 ppr, max. 600 kHz
1 Vpp sin/cos, max. 100 kHz
Power supply
4,75 VDC up to 5,5 VDC
Current consumption: typ. 100 mA
5 VDC up to 30 VDC
Current consumption: typ. 70 mA
10 VDC up to 30 VDC
Current consumption: typ. 100 mA

Environmental data

ESD (DIN EN 61000-4-2):

8 kV

Burst (DIN EN 61000-4-4):

2 kV

includes EMC:

DIN EN 61000-6-2
DIN EN 61000-6-3

Vibration:
(DIN EN 60068-2-6)

50 m/s2 (10 Hz up to 2000 Hz)

Shock:
(DIN EN 60068-2-27)

1000 m/s2 (6 ms)

Design:

according DIN VDE 0160

Duty information

Customs tariff number:

90318020

Country of origin:

Germany

Operating temperature
-20 °C up to +80 °C
1 Vpp: -10 °C up to +70 °C
Protection class
IP67+IP69K all around. Resistance to salt mist (IEC 60068-2-11) after 672 hours.
STEP viewer / STEP data:

Your desired STEP file is not listed:
Request STEP file here

DescriptionABN inv. poss.
K2axial, shield not connected
L2axial, shield connected to encoder housing
Assignments
 K2, L2K2, L2K2, L2K2, L2L2
CircuitG05, G24F05, H05, F24, H24, H30I05, I24, 524P05, R05, P24, R24, 245, 645, R30SIN
GNDWHWHWHWHWH
(+) VccBNBNBNBNBN
AGNGNGNGNGN
BYEYEYEYEGY
NGYGYGYGY-
Light reserve warningPK-PK--
A inv.--RDRDYE
B inv.--BUBUPK
N inv.--VTVT-
Shieldflexflexflexflexflex
STEP viewer / STEP data:

Your desired STEP file is not listed:
Request STEP file here

DescriptionABN inv. poss.
K3radial, shield not connected
L3radial, shield connected to encoder housing
Assignments
 K3, L3K3, L3K3, L3K3, L3L3
CircuitG05, G24F05, H05, F24, H24, H30I05, I24, 524P05, R05, P24, R24, 245, 645, R30SIN
GNDWHWHWHWHWH
(+) VccBNBNBNBNBN
AGNGNGNGNGN
BYEYEYEYEGY
NGYGYGYGY-
Light reserve warningPK-PK--
A inv.--RDRDYE
B inv.--BUBUPK
N inv.--VTVT-
Shieldflexflexflexflexflex
up to 2500 PPR
Power supply VDC
5 - 30 VDC
Current consumption
typ. 70 mA
Signal shape
square-wave
Output circuit
HTL (TTL at 5 VDC)
Channels
AB, ABN
Output
push-pull
Load
max. 40 mA / channel
Signal level mA
at 20 mA
Signal level H>
H > Vcc -10% Vcc
Signal level L<
L < 2.5 VDC
Output frequency
max. 200 kHz
Circuit protection
inverse-polarity protection only
Light reserve warning
no
Power supply VDC
5 - 30 VDC
Current consumption
typ. 70 mA
Signal shape
square-wave
Output circuit
HTL, inv. (TTL/RS422 comp. at 5 VDC)
Channels
AB, ABN, and inverted signals
Output
push-pull
Load
max. 40 mA / channel
Signal level mA
at 20 mA
Signal level H>
H > Vcc -10% Vcc
Signal level L<
L < 2.5 VDC
Output frequency
max. 200 kHz
Circuit protection
inverse-polarity protection only
Light reserve warning
no
up to 5000 PPR
Power supply VDC
4.75 - 5.5 VDC
Current consumption
typ. 70 mA
Signal shape
square-wave
Output circuit
TTL
Channels
ABN
Output
push-pull
Load
max. 40 mA / channel
Signal level mA
at 20 mA
Signal level H>
H > 2.5 VDC
Signal level L<
L < 0.5 VDC
Output frequency
max. 200 kHz
Circuit protection
no
Light reserve warning
yes
Power supply VDC
4.75 - 5.5 VDC
Current consumption
typ. 70 mA
Signal shape
square-wave
Output circuit
TTL
Channels
AB, ABN
Output
push-pull
Load
max. 40 mA / channel
Signal level mA
at 20 mA
Signal level H>
H > 2.5 VDC
Signal level L<
L < 0.5 VDC
Output frequency
max. 200 kHz
Circuit protection
no
Light reserve warning
no
Power supply VDC
4.75 - 5.5 VDC
Current consumption
typ. 70 mA
Signal shape
square-wave
Output circuit
TTL, RS422 comp., inverted
Channels
AB, ABN, and inverted signals
Output
push-pull
Load
max. 40 mA / channel
Signal level mA
at 20 mA
Signal level H>
H > 2.5 VDC
Signal level L<
L < 0.5 VDC
Output frequency
max. 200 kHz
Circuit protection
no
Light reserve warning
yes
Power supply VDC
4.75 - 5.5 VDC
Current consumption
typ. 70 mA
Signal shape
square-wave
Output circuit
TTL, RS422 comp., inverted
Channels
AB, ABN, and inverted signals
Output
push-pull
Load
max. 40 mA / channel
Signal level mA
at 20 mA
Signal level H>
H > 2.5 VDC
Signal level L<
L < 0.5 VDC
Output frequency
max. 200 kHz
Circuit protection
no
Light reserve warning
no
Power supply VDC
10 - 30 VDC
Current consumption
typ. 70 mA
Signal shape
square-wave
Output circuit
HTL
Channels
AB, ABN
Output
push-pull
Load
max. 40 mA / channel
Signal level mA
at 20 mA
Signal level H>
H > Vcc -2.5 VDC
Signal level L<
L < 2.5 VDC
Output frequency
max. 200 kHz
Circuit protection
yes
Light reserve warning
yes
Power supply VDC
10 - 30 VDC
Current consumption
typ. 70 mA
Signal shape
square-wave
Output circuit
HTL
Channels
AB, ABN
Output
push-pull
Load
max. 40 mA / channel
Signal level mA
at 20 mA
Signal level H>
H > Vcc -2.5 VDC
Signal level L<
L < 2.5 VDC
Output frequency
max. 200 kHz
Circuit protection
yes
Light reserve warning
no
Power supply VDC
10 - 30 VDC
Current consumption
typ. 70 mA
Signal shape
square-wave
Output circuit
HTL inverted
Channels
AB, ABN, and inverted signals
Output
push-pull
Load
max. 40 mA / channel
Signal level mA
at 20 mA
Signal level H>
H > Vcc -2.5 VDC
Signal level L<
L < 2.5 VDC
Output frequency
max. 200 kHz
Circuit protection
yes
Light reserve warning
yes
Power supply VDC
10 - 30 VDC
Current consumption
typ. 70 mA
Signal shape
square-wave
Output circuit
HTL inverted
Channels
AB, ABN, and inverted signals
Output
push-pull
Load
max. 40 mA / channel
Signal level mA
at 20 mA
Signal level H>
H > Vcc -2.5 VDC
Signal level L<
L < 2.5 VDC
Output frequency
max. 200 kHz
Circuit protection
yes
Light reserve warning
no
Power supply VDC
10 - 30 VDC
Current consumption
typ. 70 mA
Signal shape
square-wave
Output circuit
TTL, RS422 comp., inverted
Channels
AB, ABN, and inverted signals
Output
push-pull
Load
max. 40 mA / channel
Signal level mA
at 20 mA
Signal level H>
H > 2.5 VDC
Signal level L<
L < 1.2 VDC
Output frequency
max. 200 kHz
Circuit protection
inverse-polarity protection only
Light reserve warning
yes
Power supply VDC
10 - 30 VDC
Current consumption
typ. 70 mA
Signal shape
square-wave
Output circuit
TTL, RS422 comp., inverted
Channels
AB, ABN, and inverted signals
Output
push-pull
Load
max. 40 mA / channel
Signal level mA
at 20 mA
Signal level H>
H > 2.5 VDC
Signal level L<
L < 1.2 VDC
Output frequency
max. 200 kHz
Circuit protection
inverse-polarity protection only
Light reserve warning
no
(higher frequency) 1200 up to 25000 PPR
Power supply VDC
4.75 - 5.5 VDC
Current consumption
typ. 100 mA
Signal shape
square-wave
Output circuit
TTL
Channels
AB, ABN
Output
push-pull
Load
max. 40 mA / channel
Signal level mA
at 20 mA
Signal level H>
H > 2.5 VDC
Signal level L<
L < 0.5 VDC
Output frequency
max. 2 MHz
Circuit protection
no
Light reserve warning
no
Power supply VDC
4.75 - 5.5 VDC
Current consumption
typ. 100 mA
Signal shape
square-wave
Output circuit
TTL, RS422 comp., inverted
Channels
AB, ABN, and inverted signals
Output
push-pull
Load
max. 40 mA / channel
Signal level mA
at 20 mA
Signal level H>
H > 2.5 VDC
Signal level L<
L < 0.5 VDC
Output frequency
max. 2 MHz
Circuit protection
no
Light reserve warning
no
Power supply VDC
10 - 30 VDC
Current consumption
typ. 100 mA
Signal shape
square-wave
Output circuit
HTL
Channels
ABN
Output
push-pull
Load
max. 40 mA / channel
Signal level mA
at 20 mA
Signal level H>
H > Vcc -2.5 VDC
Signal level L<
L < 2.5 VDC
Output frequency
max. 600 kHz
Circuit protection
yes
Light reserve warning
no
Power supply VDC
10 - 30 VDC
Current consumption
typ. 100 mA
Signal shape
square-wave
Output circuit
HTL inverted
Channels
AB, ABN, and inverted signals
Output
push-pull
Load
max. 40 mA / channel
Signal level mA
at 20 mA
Signal level H>
H > Vcc -2.5 VDC
Signal level L<
L < 2.5 VDC
Output frequency
max. 600 kHz
Circuit protection
yes
Light reserve warning
no
Power supply VDC
10 - 30 VDC
Current consumption
typ. 100 mA
Signal shape
square-wave
Output circuit
TTL, RS422 comp., inverted
Channels
AB, ABN, and inverted signals
Output
push-pull
Load
max. 40 mA / channel
Signal level mA
at 20 mA
Signal level H>
H > 2.5 VDC
Signal level L<
L < 1.2 VDC
Output frequency
max. 2 MHz
Circuit protection
inverse-polarity protection only
Light reserve warning
no
1024, 2048 PPR
Power supply VDC
4.75 - 5.5 VDC
Current consumption
typ. 100 mA without load
Signal shape
sinus
Output circuit
1 Vpp sin/cos
Channels
AB
Output
Sinus, Cosinus
Load
@ 1 Vpp sin/cos: min. 120 Ohm
Signal level
1 Vpp +/- 25 %
Output frequency
max. 100 kHz
Circuit protection
no
Cabel lenght max.
max. 150 m at <260 pF/m
Light reserve warning
no
The encoder WDG 58V can be supplied with more than 2 m cable. The maximum cable length depends on the supply voltage and the frequency; see 'General Technical Data'
Please extend the standard order code with a three figure number, specifying the cable length in decimetres.
Example: 5 m cable = 050
General technical Data and safety instructions incremental encoders
General technical Data and safety instructions incremental encoders WDG/WDGI

Kurzkatalog Drehgeber - Short catalogue encoders
Short-Catalogue Encoders and systems

  • Incremental and absolute encoders
  • Digital shaft copying
  • Made in Germany
  • Motorfeedback
  • Position Measurement Systems

Food Industry
Food Industry

Automated control of the cutting thanks to profile detection

Delivery times and service
Delivery times and service

of Wachendorff Automation GmbH & Co. KG

Assembly instructions shaft encoders
Assembly instructions shaft encoders WDG/WDGI

Whitepaper optisch und magnetisch Inkremental
Whitepaper


Comparison of optical and magnetic incremental encoders

Expertise EHEDG (Hygienic test)
Expertise EHEDG (Hygienic test)

Verification of the cleanability of the encoder type WDG 58V according to the recommendations of the EHEDG (European Hygienic Engineering & Design Group).

ECOLAB Certificate of the tested resistance of material
ECOLAB - Certificate of the tested resistance of material

against the detergent and desinfectants P3-topactive DES, P3-topax 19, P3-topax 56, P3-topax 66 and P3-topax 91, as well as demineralised water as zero value.

CE Konformitätserklärungen WDG / WDGI
EC declaration of conformity incremental encoder WDG / WDGI

for Wachendorff Automation GmbH & Co. KG.

UKCA-Declaration of conformity WDG/WDGI
UKCA declaration of conformity incremental encoder WDG / WDGI

for Wachendorff Automation GmbH & Co. KG.

UL Certificates for Wachendorff Automation Products 2014-03-28
UL Certificates

for Wachendorff Automation products.

REACH regulation
REACH- and RoHS regulation of the EU

Information

ISO Zertifikat DIN EN 9001:2015
ISO Certificate DIN EN 9001:2015

distributors
For further information please contact our local distributor.
Here you find a list of our distributors worldwide
You want to get an offer or want a recall. Request