Shaft Encoder incremental, optical,
Resolution: up to 25000 ppr,
Clamping flange: Ø 58 mm
Especially for food and beverage industry
Acid- and alkaline resistance
Shaft: Ø 10 mm,
Protection rating: IP67 + IP69K,
Signal shape: square-wave or sine/cosine.
- EHEDG: Tested hygienic design
- Resistance to Salt mist acc. (IEC 60068-2-11)
- Up to 25000 PPR by use of high grad electronics
- Ecolab: Certificate on resistance to cleaning and disinfection agents
- High protection rating IP67 all around and IP69K
(high pressure / steam cleaning) - Radial shaft sealing ring with no dead-room (PTFE)
- Full connection protection with 10 VDC up to 30 VDC
- With light reserve warning
Shaft length: L: 18 mm
Max. Permissible shaft loading radial: 100 N
Max. Permissible shaft loading axial: 100 N
Current consumption: typ. 100 mA
Current consumption: typ. 70 mA
Current consumption: typ. 100 mA
Environmental data
ESD (DIN EN 61000-4-2):
8 kV
Burst (DIN EN 61000-4-4):
2 kV
includes EMC:
DIN EN 61000-6-2
DIN EN 61000-6-3
Vibration:
(DIN EN 60068-2-6)
50 m/s2 (10 Hz up to 2000 Hz)
Shock:
(DIN EN 60068-2-27)
1000 m/s2 (6 ms)
Design:
according DIN VDE 0160
Duty information
Customs tariff number:
90318020
Country of origin:
Germany
1 Vpp: -10 °C up to +70 °C
Description | ABN inv. poss. | |
---|---|---|
K2 | axial, shield not connected | ● |
L2 | axial, shield connected to encoder housing | ● |
K2, L2 | K2, L2 | K2, L2 | K2, L2 | L2 | |
Circuit | G05, G24 | F05, H05, F24, H24, H30 | I05, I24, 524 | P05, R05, P24, R24, 245, 645, R30 | SIN |
GND | WH | WH | WH | WH | WH |
(+) Vcc | BN | BN | BN | BN | BN |
A | GN | GN | GN | GN | GN |
B | YE | YE | YE | YE | GY |
N | GY | GY | GY | GY | - |
Light reserve warning | PK | - | PK | - | - |
A inv. | - | - | RD | RD | YE |
B inv. | - | - | BU | BU | PK |
N inv. | - | - | VT | VT | - |
Shield | flex | flex | flex | flex | flex |
Description | ABN inv. poss. | |
---|---|---|
K3 | radial, shield not connected | ● |
L3 | radial, shield connected to encoder housing | ● |
K3, L3 | K3, L3 | K3, L3 | K3, L3 | L3 | |
Circuit | G05, G24 | F05, H05, F24, H24, H30 | I05, I24, 524 | P05, R05, P24, R24, 245, 645, R30 | SIN |
GND | WH | WH | WH | WH | WH |
(+) Vcc | BN | BN | BN | BN | BN |
A | GN | GN | GN | GN | GN |
B | YE | YE | YE | YE | GY |
N | GY | GY | GY | GY | - |
Light reserve warning | PK | - | PK | - | - |
A inv. | - | - | RD | RD | YE |
B inv. | - | - | BU | BU | PK |
N inv. | - | - | VT | VT | - |
Shield | flex | flex | flex | flex | flex |
up to 2500 PPR
up to 5000 PPR
(higher frequency) 1200 up to 25000 PPR
1024, 2048 PPR
Please extend the standard order code with a three figure number, specifying the cable length in decimetres.
Example: 5 m cable = 050
- Incremental and absolute encoders
- Digital shaft copying
- Made in Germany
- Motorfeedback
- Position Measurement Systems
Automated control of the cutting thanks to profile detection
of Wachendorff Automation GmbH & Co. KG
Comparison of optical and magnetic incremental encoders
Verification of the cleanability of the encoder type WDG 58V according to the recommendations of the EHEDG (European Hygienic Engineering & Design Group).
against the detergent and desinfectants P3-topactive DES, P3-topax 19, P3-topax 56, P3-topax 66 and P3-topax 91, as well as demineralised water as zero value.
for Wachendorff Automation GmbH & Co. KG.
for Wachendorff Automation GmbH & Co. KG.
for Wachendorff Automation products.
Information
Here you find a list of our distributors worldwide