WDGA 36E RS485
Absolute hollow bore (blind) encoder, magnetic, RS485 WDGA 36E
Housing: Ø 36 mm
16/32-bit Single-turn/Multi-turn;
hollow bore (blind): Ø 6 mm, Ø 1/4",
CRC checksum
Highlights
- EnDra® multiturn technology:
maintenance-free and environmentally friendly - Compact industrial model
- Interface: RS485
- Preset input
- Direction of counting changeable
- Status indicator LED
- EMC: EN 61000-6-2, EN 61000-6-3
Product details
Flange
hollow shaft (blind-bored)
Housing
Ø 36 mm
stainless steel
Resolution
Single-turn Resolution
up to 65,536 steps/360° (16 bit)
Multi-turn Resolutionup to 32 bit.
Shaft
Ø 6 mm
Insertion depth min.: 8 mm
Insertion depth max.: 17 mm
Max. Permissible shaft loading radial: 80 N
Max. Permissible shaft loading axial: 50 N
Insertion depth min.: 8 mm
Insertion depth max.: 17 mm
Max. Permissible shaft loading radial: 80 N
Max. Permissible shaft loading axial: 50 N
Ø 6.35 mm, Ø 1/4"
Insertion depth min.: 8 mm
Insertion depth max.: 17 mm
Max. Permissible shaft loading radial: 80 N
Max. Permissible shaft loading axial: 50 N
Insertion depth min.: 8 mm
Insertion depth max.: 17 mm
Max. Permissible shaft loading radial: 80 N
Max. Permissible shaft loading axial: 50 N
Max. operating speed
12000 rpm
Power supply
4,75 VDC up to 32 VDC
Current consumption: typ. 50 mA
Power consumption: max. 0.5 W
Current consumption: typ. 50 mA
Power consumption: max. 0.5 W
4,75 VDC up to 5,5 VDC
Current consumption: typ. 80 mA
Power consumption: max. 0.44 W
Current consumption: typ. 80 mA
Power consumption: max. 0.44 W
Operating temperature
-40 °C up to +85 °C
Storage temperature
-40 °C up to +100 °C
Protection class
Housing: IP65, IP67; shaft sealed: IP65; cable outlet K1: IP40
Description | |
---|---|
L2 | axial, shield connected to encoder housing |
Assignments
S- (GND) | WH |
S+ (DCin) | BN |
A (DATA+) | GY |
B (DATA-) | PK |
PRESET | BU |
DIR | RD |
Shield | housing |
Description | |
---|---|
L3 | radial, shield connected to encoder housing |
Assignments
S- (GND) | WH |
S+ (DCin) | BN |
A (DATA+) | GY |
B (DATA-) | PK |
PRESET | BU |
DIR | RD |
Shield | housing |
Description | |
---|---|
K1 | radial, shield not connected |
Assignments
S- (GND) | WH |
S+ (DCin) | BN |
A (DATA+) | GY |
B (DATA-) | PK |
PRESET | BU |
DIR | RD |
Shield | housing n. c. |
Description | |
---|---|
CB8 | axial, 8-pin, shield connected to encoder housing |
Description | |
---|---|
CC8 | radial, 8-pin, shield connected to encoder housing |
Motor feedback installation solutions with EnDra® Technology
...to be directly installed in motors.
Download (1.39 MB)
Handout Absolute encoders WDGA
- Absolute encoders with flange Ø 36 mm / Ø 58 mm
- Single-/Multiturn (16/43)
- Ground-breaking technology 32 Bit processor
- Very high shaft loading, IP67
- EnDra® Multiturn technology: No gears, no battery
- QuattroMag® Singleturn technology: High precision +/- 0,0878°
Download (1.34 MB)
Short-Catalogue Encoders and systems
- Incremental and absolute encoders
- Digital shaft copying
- Made in Germany
- Motorfeedback
- Position Measurement Systems
Download (4.24 MB)
KI-8-67-EIA
Female connector KI-8-67-EIA:
Suitable for encoder absolute WDGA RS485
with connector outlet CB8 and CC8, 8 pin, IP67
Ready-made shielded connection cable
with female cable connector straight, shield connected.
KIA-8-67-EIA
Female connector KIA-8-67-EIA:
Suitable for encoder absolute WDGA RS485
with sensor connector outlet CB8 and CC8, 8 pin, IP67
Ready-made shielded connection cable
with female cable connector angular, shield connected.
For further information please contact our local distributor.
Here you find a list of our distributors worldwide
Here you find a list of our distributors worldwide
You want to get an offer or want a recall. Request