WDGI 63B

Shaft Encoder incremental, optical,
resolution: up to 25000 ppr,
Clamping flange: Ø 2.5" (63 mm)

Dimensions inches and mm,
Shaft: Ø 3/8" (9.525 mm), 10 mm,
Ø 7 mm / Ø 8 mm on request,
protection rating: up to IP67 all around,
Signal shape: square-wave or sine/cosine.

Data sheet General technical data incremental encoders (PDF 838 kB)
Drehgeber WDGI63B
Highlights
  • Housing cap die cast aluminum,
    with particularly eco-friendly powder coating
  • Up to 25000 PPR by use of high grad electronics
  • Protection to IP67, shaft sealed to IP65
  • Full connection protection with 10 VDC up to 30 VDC
  • High output frequency 600 kHz/2 MHz
  • Optional:
    -40 °C up to +85 °C [-40 °F à +185 °F],
    Protection to IP67 all around,
    Pressure equalising membrane
Product details
Flange
clamping flange
Pulses per revolution PPR
up to 25000 PPR
Housing
Ø 63.5 mm [Ø 2.5 in]
die cast aluminum, powder coated
Shaft
Ø 9.525 mm, Ø 3/8"
Shaft length: L: 22.3 mm, L: 0.878 in
Max. Permissible shaft loading radial: 220 N, 22.434 kp
Max. Permissible shaft loading axial: 120 N, 12.237 kp
Ø 10 mm
Shaft length: L: 20 mm
Max. Permissible shaft loading radial: 220 N
Max. Permissible shaft loading axial: 120 N
Advice: Ø 7 mm / Ø 8 mm on request
Max. operating speed
8000 rpm
Output circuit
TTL
TTL, RS422 compatible, inv.
HTL
HTL, inv.
1 Vpp sin/cos
Output frequency
TTL ≤ 5000 ppr, max. 200 kHz
HTL ≤ 5000 ppr, max. 200 kHz
TTL more than 1200 ppr, max. 2 MHz
HTL more than 1200 ppr, max. 600 kHz
1 Vpp sin/cos, max. 100 kHz
Power supply
4,75 VDC up to 5,5 VDC
Current consumption: typ. 100 mA
5 VDC up to 30 VDC
Current consumption: typ. 70 mA
10 VDC up to 30 VDC
Current consumption: typ. 100 mA

Environmental data

ESD (DIN EN 61000-4-2):

8 kV

Burst (DIN EN 61000-4-4):

2 kV

includes EMC:

DIN EN 61000-6-2
DIN EN 61000-6-3

Vibration:
(DIN EN 60068-2-6)

50 m/s2 (10 Hz up to 2000 Hz)

Shock:
(DIN EN 60068-2-27)

1000 m/s2 (6 ms)

Design:

according DIN VDE 0160

Duty information

Customs tariff number:

90318020

Country of origin:

Germany

Operating temperature
Connector: -40 °C up to +85 °C, cable: -20 °C up to +80 °C, (Option ACA: -40 °C up to +85 °C) [Connector: -4 °F up to +185 °F, cable: -4 °F up to +176 °F, (Option ACA: -40 °F up to +185 °F)]
1 Vpp: -10 °C up to +70 °C [+14 °F up to +158 °F]
Protection class
Housing: IP65, IP67; shaft sealed: IP65
STEP viewer / STEP data:

Your desired STEP file is not listed:
Request STEP file here

Description ABN inv. poss.
K2 axial, shield not connected
L2 axial, shield connected to encoder housing
Assignments
 
Circuit
GND
(+) Vcc
A
B
N
Light reserve warning
A inv.
B inv.
N inv.
Shield
STEP viewer / STEP data:

Your desired STEP file is not listed:
Request STEP file here

Description ABN inv. poss.
K3 radial, shield not connected
L3 radial, shield connected to encoder housing
Assignments
 
Circuit
GND
(+) Vcc
A
B
N
Light reserve warning
A inv.
B inv.
N inv.
Shield
STEP viewer / STEP data:

Your desired STEP file is not listed:
Request STEP file here

Description ABN inv. poss.
SI5 axial, 5-pin, Connector connected to encoder housing-
SI6 axial, 6-pin, Connector connected to encoder housing-
SI8 axial, 8-pin, Connector connected to encoder housing
SI12 axial, 12-pin, Connector connected to encoder housing
Assignments
 
connector drawing
Circuit
GND
(+) Vcc
A
B
N
Light reserve warning
A inv.
B inv.
N inv.
n. c.
Shield
STEP viewer / STEP data:

Your desired STEP file is not listed:
Request STEP file here

Description ABN inv. poss.
SH5 radial, 5-pin, Connector connected to encoder housing-
SH6 radial, 6-pin, Connector connected to encoder housing-
SH8 radial, 8-pin, Connector connected to encoder housing
SH12 radial, 12-pin, Connector connected to encoder housing
Assignments
 
connector drawing
Circuit
GND
(+) Vcc
A
B
N
Light reserve warning
A inv.
B inv.
N inv.
n. c.
Shield
STEP viewer / STEP data:

Your desired STEP file is not listed:
Request STEP file here

Description ABN inv. poss.
S2 axial, 7-pin, Connector connected to encoder housing-
Assignments
 
connector drawing
Circuit
GND
(+) Vcc
A
B
N
Light reserve warning
A inv.
B inv.
N inv.
n. c.
Shield
STEP viewer / STEP data:

Your desired STEP file is not listed:
Request STEP file here

Description ABN inv. poss.
S3 radial, 7-pin, Connector connected to encoder housing-
Assignments
 
connector drawing
Circuit
GND
(+) Vcc
A
B
N
Light reserve warning
A inv.
B inv.
N inv.
n. c.
Shield
STEP viewer / STEP data:

Your desired STEP file is not listed:
Request STEP file here

Description ABN inv. poss.
S4 axial, 12-pin, Connector connected to encoder housing
Assignments
 
connector drawing
Circuit
GND
(+) Vcc
A
B
N
Light reserve warning
A inv.
B inv.
N inv.
n. c.
Shield
STEP viewer / STEP data:

Your desired STEP file is not listed:
Request STEP file here

Description ABN inv. poss.
S5 radial, 12-pin, Connector connected to encoder housing
Assignments
 
connector drawing
Circuit
GND
(+) Vcc
A
B
N
Light reserve warning
A inv.
B inv.
N inv.
n. c.
Shield
STEP viewer / STEP data:

Your desired STEP file is not listed:
Request STEP file here

Description ABN inv. poss.
S4R axial, 12-pin, Connector connected to encoder housing
Assignments
 
connector drawing
Circuit
GND
(+) Vcc
A
B
N
Light reserve warning
A inv.
B inv.
N inv.
n. c.
Shield
STEP viewer / STEP data:

Your desired STEP file is not listed:
Request STEP file here

Description ABN inv. poss.
S5R radial, 12-pin, Connector connected to encoder housing
Assignments
 
connector drawing
Circuit
GND
(+) Vcc
A
B
N
Light reserve warning
A inv.
B inv.
N inv.
n. c.
Shield
STEP viewer / STEP data:

Your desired STEP file is not listed:
Request STEP file here

Description ABN inv. poss.
SB4 axial, 4-pin, Connector connected to encoder housing-
SB5 axial, 5-pin, Connector connected to encoder housing-
SB8 axial, 8-pin, Connector connected to encoder housing
SB12 axial, 12-pin, Connector connected to encoder housing
Assignments
 
connector drawing
Circuit
GND
(+) Vcc
A
B
N
Light reserve warning
A inv.
B inv.
N inv.
n. c.
Shield
STEP viewer / STEP data:

Your desired STEP file is not listed:
Request STEP file here

Description ABN inv. poss.
SC4 radial, 4-pin, Connector connected to encoder housing-
SC5 radial, 5-pin, Connector connected to encoder housing-
SC8 radial, 8-pin, Connector connected to encoder housing
SC12 radial, 12-pin, Connector connected to encoder housing
Assignments
 
connector drawing
Circuit
GND
(+) Vcc
A
B
N
Light reserve warning
A inv.
B inv.
N inv.
n. c.
Shield
The encoder WDGI 63B can be supplied in a full IP67 version.
Max. RPM: 3500 rpm
Permitted Shaft-Loading, axial:100 N [10.197 kp]
Permitted Shaft-Loading, radial:110 N [11.217 kp]
Max. PPR: 25000 ppr
Starting-torque:approx. 4 Ncm at ambient temperature [approx. 5.6645 in-ozf at ambient temperature]
The encoder WDGI 63B with the output circuit types F24, G24, I24, P24, R24, F05, G05, H05, I05, P05, R05, 245, 524, 645 is also available with the extended temperature range -40 °C up to +85 °C [-40 °F up to +185 °F] (measured at the flange).

The WDGI 63B shaft encoder is also optionally available with a pressure equalising membrane. This prevents water from penetrating into the encoder housing in the case of high air humidity.
The IP67 protection level, temperature range and salt spray resistance are maintained. Resistant to chemicals and solvents in accordance with DIN EN ISO 2812-1.

The encoder WDGI 63B can be supplied with more than 2 m cable. The maximum cable length depends on the supply voltage and the frequency; see 'General Technical Data'
Please extend the standard order code with a three figure number, specifying the cable length in decimetres.
Example: 5 m cable = 050
General technical Data and safety instructions incremental encoders
General technical Data and safety instructions incremental encoders WDG/WDGI

Flyer Drehgeber Encoder WDGI
WDGI encoder - the new incremental industry standard

  • Die-cast aluminium housing, powder coated
  • Maximum bearing loads of up to 500 N, axial / radial
  • Self-adhesive membrane
  • High output frequency 600 kHz / 2 MHz
  • Extended operating temperature -40 °C to +85 °C

Kurzkatalog Drehgeber - Short catalogue encoders
Short-Catalogue Encoders and systems

  • Incremental and absolute encoders
  • Digital shaft copying
  • Made in Germany
  • Motorfeedback
  • Position Measurement Systems

Delivery times and service
Delivery times and service

of Wachendorff Automation GmbH & Co. KG

Assembly instructions shaft encoders
Assembly instructions shaft encoders WDG/WDGI

Whitepaper optisch und magnetisch Inkremental
Whitepaper


Comparison of optical and magnetic incremental encoders

CE Konformitätserklärungen WDG / WDGI
EC declaration of conformity incremental encoder WDG / WDGI

for Wachendorff Automation GmbH & Co. KG.

UKCA-Declaration of conformity WDG/WDGI
UKCA declaration of conformity incremental encoder WDG / WDGI

for Wachendorff Automation GmbH & Co. KG.

UL Certificates for Wachendorff Automation Products 2014-03-28
UL Certificates

for Wachendorff Automation products.

REACH regulation
REACH- and RoHS regulation of the EU

Information

ISO Zertifikat DIN EN 9001:2015
ISO Certificate DIN EN 9001:2015

KI467 Drehgeber Kabeldose
KI-4-67

Female connector KI-4-67:
Suitable for encoder with sensor connector outlet SB4 and SC4, 4 pin, IP67

Ready-made shielded connection cable with female cable connector straight,
shield connected.

KIA467 Drehgeber Kabeldose
KIA-4-67

Female connector KIA-4-67:
Suitable for encoder with sensor connector outlet SB4 and SC4, 4 pin, IP67

Ready-made shielded connection cable with female cable connector angular,
shield connected.

KI567 Drehgeber Kabeldose
KI-5-67

Female connector KI-5-67:
Suitable for encoder with sensor connector outlet SB5 and SC5, 5 pin, IP67

Ready-made shielded connection cable with female cable connector straight,
shield connected.

KIA567 Drehgeber Kabeldose
KIA-5-67

Female connector KIA-5-67:
Suitable for encoder with sensor connector outlet SB5 and SC5, 5 pin, IP67

Ready-made shielded connection cable with female cable connector angular,
shield connected.

KD540 Drehgeber Kabeldose
KD-5-40

Female connector KD-5-40:
Suitable for encoder with connector outlet SI/SH, 5 pin, IP40

Straight female connector or
straight connector with ready made cable.
With female thread M16 x 0.75.

KD567 Kabeldose Drehgeber
KD-5-67

Female connector KD-5-67:
Suitable for encoder with connector outlet SI/SH, 5 pin, IP67

Straight female connector or
straight connector with ready made cable.
With female thread M16 x 0.75.

KDA667 Drehgeber Kabeldose
KDA-6-67

Female connector KDA-6-67:
Suitable for encoder with connector outlet SI/SH, 6 pin, IP67

Angular female connector or
angular connector with ready made cable.

KD740 Drehgeber Kabeldose
KD-7-40

Female connector KD-7-40:
Suitable for encoder with connector outlet S2/S3,, 7 pin, IP40

Straight female connector or
straight connector with ready made cable.
With female thread M16 x 0.75.

KDA740 Drehgeber Kabeldose
KDA-7-40

Female connector KDA-7-40:
Suitable for encoder with connector outlet S2/S3, 7 pin, IP40

Angular female connector or
angular connector with ready made cable.
With female thread M16 x 0.75.

KD767 Drehgeber Kabeldose
KD-7-67

Female connector KD-7-67:
Suitable for encoder with connector outlet S2/S3, 7 pin, IP67

Straight female connector or
straight connector with ready made cable.
With female thread M16 x 0.75.

KDA767 Drehgeber Kabeldose
KDA-7-67

Female connector KDA-7-67:
Suitable for encoder with connector outlet S2/S3, 7 pin, IP67

Angular female connector or
angular connector with ready made cable.
With female thread M16 x 0.75.

KI867 Drehgeber Kabeldose
KI-8-67

Female connector KI-8-67:
Suitable for encoder with sensor connector outlet SB8 and SC8, 8 pin, IP67

Ready-made shielded connection cable with female cable connector straight,
shield connected.

KIA867 Drehgeber Kabeldose
KIA-8-67

Female connector KIA-8-67:
Suitable for encoder with sensor connector outlet SB8 and SC8, 8 pin, IP67

Ready-made shielded connection cable with female cable connector angular,
shield connected.

KD840 Drehgeber Kabeldose
KD-8-40

Female connector KD-8-40:
Suitable for encoder with connector outlet SI/SH, 8 pin, IP40

Straight female connector or
straight female connector with ready made cable.

KD867 Drehgeber Kabeldose
KD-8-67

Female connector KD-8-67:
Suitable for encoder with connector outlet SI/SH, 8 pin, IP67

Straight female connector or
straight female connector with ready made cable.

Drehgeber KDA867
KDA-8-67

Female connector KDA-8-67:
Suitable for encoder with connector outlet SI/SH, 8 pin, IP67

Angular female connector or
angular connector with ready made cable.
With female thread M16 x 0.75.

Drehgeber KDA867S
KDA-8-67-S

Female connector KDA-8-67-S:
Suitable for encoder with connector outlet SI/SH, 8 pin, IP67

Angular female connector, shieldable or
angular connector with ready made cable, shield connected.

KI1267 Drehgeber Kabeldose
KI-12-67

Female connector KI-12-67:
Suitable for encoder with sensor connector outlet SB12 and SC12, 12 pin, IP67

Ready-made shielded connection cable with female cable connector straight,
shield connected.

KIA1267 Drehgeber Kabeldose
KIA-12-67

Female connector KIA-12-67:
Suitable for encoder with sensor connector outlet SB12 and SC12, 12 pin, IP67

Ready-made shielded connection cable with female cable connector angular,
shield connected.

KDSH1267 Drehgeber Kabeldose
KD-SH12-67

Female connector KD-SH12-67:
Suitable for encoder with connector outlet SI/SH, 12 pin, IP67

Straight female connector or
straight connector with ready made cable.

KD1267 Drehgeber Kabeldose
KD-12-67

Female connector KD-12-67:
Suitable for encoder with connector outlet S4/S5, S4R/S5R, 12 pin, IP67

Straight female connector or
straight connector with ready made cable.
clockwise or anti-clockwise.

 STEP-file

KDA1267 Drehgeber Kabeldose
KDA-12-67

Female connector KDA-12-67:
Suitable for encoder with connector outlet S4/S5, S4R/S5R, 12 pin, IP67

Angular female connector or
angular connector with ready made cable.
Clockwise or anti-clockwise.
Insert any mountable.

KD84015S DIZ Drehgeber Kabeldose
KD-8-40-15-S-DIZ

Female connector KD-8-40-15-S-DIZ:
For frequency inverters: Emotron

Suitable for encoder with connector outlet SI8 and SH8, 8 pin, IP40.
Connector (Sub-D 15 pin, 2 rows).
Ready-made shielded connection cable with female cable connector straight and Sub-D connector.
Female connector/ housing / connector housing electrically connected.

KD84015S RST Drehgeber Kabeldose
KD-8-40-15-S-RST

Female connector KD-8-40-15-S-RST:
For frequency inverters: RST

Suitable for encoder with connector outlet SI8 and SH8, 8 pin, IP40.
Connector (Sub-D 15 pin, 2 rows).
Ready-made shielded connection cable with female cable connector straight and Sub-D connector.
Female connector/ housing / connector housing electrically connected.

KD84015S SDR Drehgeber Kabeldose
KD-8-40-15-S-SDR

Female connector KD-8-40-15-S-SDR:
For controller: Schindler MX

Suitable for encoder with connector outlet SI8 and SH8, 8 pin, IP40.
Connector (Sub-D 15 pin, 2 rows).
Ready-made shielded connection cable with female cable connector straight and Sub-D connector
Female connector/ housing / connector housing electrically connected.

KD84015S CTF Drehgeber Kabeldose
KD-8-40-15-S-CTF

Female connector KD-8-40-15-S-CTF:
For frequency inverters: Control Techniques

Suitable for encoder with connector outlet SI8 and SH8, 8 pin, IP40.
Connector (Sub-D 15 pin, 3 rows).
Ready-made shielded connection cable with female cable connector straight and Sub-D connector
Female connector/ housing / connector housing electrically connected.

KD84015S KEB Drehgeber Kabeldose
KD-8-40-15-S-KEB

Female connector KD-8-40-15-S-KEB:
For frequency inverters: KEB

Suitable for encoder with connector outlet SI8 and SH8, 8 pin, IP40.
connector (Sub-D 15 pin, 3 rows).
Ready-made shielded connection cable with female cable connector straight and Sub-D connector
Female connector/ housing / connector housing electrically connected.

KD84015S LOH Drehgeber Kabeldose
KD-8-40-15-S-LOH

Female connector KD-8-40-15-S-LOH:
For frequency inverters: Flender Loher, type Dynavert L

Suitable for encoder with connector outlet SI8 and SH8, 8 pin, IP40.
connector (Sub-D 15 pin, 3 rows).
Ready-made shielded connection cable with female cable connector straight and Sub-D connector
Female connector/ housing / connector housing electrically connected.

KD84015S LIF Drehgeber Kabeldose
KD-8-40-15-S-LIF

Female connector KD-8-40-15-S-LIF:
For frequency inverters: Liftequip

Suitable for encoder with connector outlet SI8 and SH8, 8 pin, IP40.
Connector (Sub-D 9 pin, 2 rows).
Ready-made shielded connection cable with female cable connector straight and Sub-D connector.
Female connector/ housing / connector housing electrically connected.

KD84015S ZIL Drehgeber Kabeldose
KD-8-40-15-S-ZIL

Female connector KD-8-40-15-S-ZIL:
For frequency inverters: Ziehl-Abegg

Suitable for encoder with connector outlet SI8 and SH8, 8 pin, IP40.
connector (Sub-D 9 pin, 2 rows).
Ready-made shielded connection cable with female cable connector straight and Sub-D connector.
Female connector/ housing / connector housing electrically connected.

SP300 Drehgeber Spannexzenter
SP-3-00

Clamping claw SP-3-00

suitable for incremental encoder WDG 40A, 50B, 58T, WDGI 58A, 58B, 58C, 58D, 58K, 63B, WDGP 36A, WDGP 58A, WDGP 58B and absolute encoder WDGA 36A, WDGA 58A, WDGA 58B.

STEP file

Generally encoder specifications

Incremental encoder specifications

###field_inkr_fruhwarnausgang###
###field_inkr_ascode###

Electrical connection

Cable outlet
Connector

Your configured order code

ShaftPPRChannelsOutputConnectionOption
WDGI 63B
distributors
For further information please contact our local distributor.
Here you find a list of our distributors worldwide
You want to get an offer or want a recall. Request