Hollow Bore (blind) Encoder incremental, magnetic,
Resolution: up to 1024 ppr,
WDGI 58E: Ø 58 mm
Bore size Ø 12 mm;
Ø 6, 6.35 (1/4''), 7, 8, 9.525 (3/8''), 10 mm with adapter sleeve;
Protection rating: IP67, shaft sealed to IP65,
Signal shape: square-wave
- Rugged industrial standard end hollow shaft encoder
- Housing cap die cast aluminum,
with particularly eco-friendly powder coating - Maximum mechanical and electrical safety
- High protection accordingt IP67, shaft sealed to IP65, high noise immunity
- Hollow bore (blind)
- Optional: -40 °C up to +85 °C,
Pressure equalising membrane
Advice: with adapter sleeve
Shaft length: L: 16 mm
Insertion depth min.: 11 mm
Insertion depth max.: 19 mm
Max. Permissible shaft loading radial: 80 N
Max. Permissible shaft loading axial: 50 N
Advice: with adapter sleeve
Shaft length: L: 16 mm
Insertion depth min.: 11 mm
Insertion depth max.: 19 mm
Max. Permissible shaft loading radial: 80 N
Max. Permissible shaft loading axial: 50 N
Advice: with adapter sleeve
Shaft length: L: 16 mm
Insertion depth min.: 11 mm
Insertion depth max.: 19 mm
Max. Permissible shaft loading radial: 80 N
Max. Permissible shaft loading axial: 50 N
Advice: with adapter sleeve
Shaft length: L: 16 mm
Insertion depth min.: 11 mm
Insertion depth max.: 19 mm
Max. Permissible shaft loading radial: 80 N
Max. Permissible shaft loading axial: 50 N
Advice: with adapter sleeve
Shaft length: L: 16 mm
Insertion depth min.: 11 mm
Insertion depth max.: 19 mm
Max. Permissible shaft loading radial: 80 N
Max. Permissible shaft loading axial: 50 N
Advice: with adapter sleeve
Shaft length: L: 16 mm
Insertion depth min.: 11 mm
Insertion depth max.: 19 mm
Max. Permissible shaft loading radial: 80 N
Max. Permissible shaft loading axial: 50 N
Shaft length: L: 16 mm
Insertion depth min.: 11 mm
Insertion depth max.: 19 mm
Max. Permissible shaft loading radial: 80 N
Max. Permissible shaft loading axial: 50 N
Current consumption: typ. 40 mA
Environmental data
ESD (DIN EN 61000-4-2):
8 kV
Burst (DIN EN 61000-4-4):
2 kV
includes EMC:
DIN EN 61000-6-2
DIN EN 61000-6-3
Vibration:
(DIN EN 60068-2-6)
50 m/s2 (10 Hz up to 2000 Hz)
Shock:
(DIN EN 60068-2-27)
1000 m/s2 (6 ms)
Design:
according DIN VDE 0160
Duty information
Customs tariff number:
90318020
Country of origin:
Germany
Description | ABN inv. poss. | |
---|---|---|
K3 | radial, shield not connected | ● |
L3 | radial, shield connected to encoder housing | ● |
K3, L3 | K3, L3 | |
Circuit | N35 | M35 |
GND | WH | WH |
(+) Vcc | BN | BN |
A | GN | GN |
B | YE | YE |
N | GY | GY |
Light reserve warning | - | - |
A inv. | - | RD |
B inv. | - | BK, (BU at ACA) |
N inv. | - | VT |
Shield | flex | flex |
Description | ABN inv. poss. | |
---|---|---|
SH5 | radial, 5-pin, Connector connected to encoder housing | - |
SH6 | radial, 6-pin, Connector connected to encoder housing | - |
SH8 | radial, 8-pin, Connector connected to encoder housing | ● |
SH12 | radial, 12-pin, Connector connected to encoder housing | ● |
Description | ABN inv. poss. | |
---|---|---|
S3 | radial, 7-pin, Connector connected to encoder housing | - |
Description | ABN inv. poss. | |
---|---|---|
S5 | radial, 12-pin, Connector connected to encoder housing | ● |
Description | ABN inv. poss. | |
---|---|---|
S5R | radial, 12-pin, Connector connected to encoder housing | ● |
Description | ABN inv. poss. | |
---|---|---|
SC4 | radial, 4-pin, Connector connected to encoder housing | - |
SC5 | radial, 5-pin, Connector connected to encoder housing | - |
SC8 | radial, 8-pin, Connector connected to encoder housing | ● |
SC12 | radial, 12-pin, Connector connected to encoder housing | ● |
up to 1024 PPR
The WDGI 58E shaft encoder is also optionally available with a pressure equalising membrane. This prevents water from penetrating into the encoder housing in the case of high air humidity.
The IP67 protection level, temperature range and salt spray resistance are maintained. Resistant to chemicals and solvents in accordance with DIN EN ISO 2812-1.
Please extend the standard order code with a three figure number, specifying the cable length in decimetres.
Example: 5 m cable = 050
Female connector KI-4-67:
Suitable for encoder with sensor connector outlet SB4 and SC4, 4 pin, IP67
Ready-made shielded connection cable with female cable connector straight,
shield connected.
Female connector KIA-4-67:
Suitable for encoder with sensor connector outlet SB4 and SC4, 4 pin, IP67
Ready-made shielded connection cable with female cable connector angular,
shield connected.
Female connector KI-5-67:
Suitable for encoder with sensor connector outlet SB5 and SC5, 5 pin, IP67
Ready-made shielded connection cable with female cable connector straight,
shield connected.
Female connector KIA-5-67:
Suitable for encoder with sensor connector outlet SB5 and SC5, 5 pin, IP67
Ready-made shielded connection cable with female cable connector angular,
shield connected.
Female connector KD-5-40:
Suitable for encoder with connector outlet SI/SH, 5 pin, IP40
Straight female connector or
straight connector with ready made cable.
With female thread M16 x 0.75.
Female connector KD-5-67:
Suitable for encoder with connector outlet SI/SH, 5 pin, IP67
Straight female connector or
straight connector with ready made cable.
With female thread M16 x 0.75.
Female connector KDA-6-67:
Suitable for encoder with connector outlet SI/SH, 6 pin, IP67
Angular female connector or
angular connector with ready made cable.
Female connector KD-7-40:
Suitable for encoder with connector outlet S2/S3,, 7 pin, IP40
Straight female connector or
straight connector with ready made cable.
With female thread M16 x 0.75.
Female connector KDA-7-40:
Suitable for encoder with connector outlet S2/S3, 7 pin, IP40
Angular female connector or
angular connector with ready made cable.
With female thread M16 x 0.75.
Female connector KD-7-67:
Suitable for encoder with connector outlet S2/S3, 7 pin, IP67
Straight female connector or
straight connector with ready made cable.
With female thread M16 x 0.75.
Female connector KDA-7-67:
Suitable for encoder with connector outlet S2/S3, 7 pin, IP67
Angular female connector or
angular connector with ready made cable.
With female thread M16 x 0.75.
Female connector KI-8-67:
Suitable for encoder with sensor connector outlet SB8 and SC8, 8 pin, IP67
Ready-made shielded connection cable with female cable connector straight,
shield connected.
Female connector KIA-8-67:
Suitable for encoder with sensor connector outlet SB8 and SC8, 8 pin, IP67
Ready-made shielded connection cable with female cable connector angular,
shield connected.
Female connector KD-8-40:
Suitable for encoder with connector outlet SI/SH, 8 pin, IP40
Straight female connector or
straight female connector with ready made cable.
Female connector KD-8-67:
Suitable for encoder with connector outlet SI/SH, 8 pin, IP67
Straight female connector or
straight female connector with ready made cable.
Female connector KDA-8-67:
Suitable for encoder with connector outlet SI/SH, 8 pin, IP67
Angular female connector or
angular connector with ready made cable.
With female thread M16 x 0.75.
Female connector KDA-8-67-S:
Suitable for encoder with connector outlet SI/SH, 8 pin, IP67
Angular female connector, shieldable or
angular connector with ready made cable, shield connected.
Female connector KI-12-67:
Suitable for encoder with sensor connector outlet SB12 and SC12, 12 pin, IP67
Ready-made shielded connection cable with female cable connector straight,
shield connected.
Female connector KIA-12-67:
Suitable for encoder with sensor connector outlet SB12 and SC12, 12 pin, IP67
Ready-made shielded connection cable with female cable connector angular,
shield connected.
Female connector KDA-12-67:
Suitable for encoder with connector outlet S4/S5, S4R/S5R, 12 pin, IP67
Angular female connector or
angular connector with ready made cable.
Clockwise or anti-clockwise.
Insert any mountable.
Female connector KD-SH12-67:
Suitable for encoder with connector outlet SI/SH, 12 pin, IP67
Straight female connector or
straight connector with ready made cable.
Female connector KD-8-40-15-S-DIZ:
For frequency inverters: Emotron
Suitable for encoder with connector outlet SI8 and SH8, 8 pin, IP40.
Connector (Sub-D 15 pin, 2 rows).
Ready-made shielded connection cable with female cable connector straight and Sub-D connector.
Female connector/ housing / connector housing electrically connected.
Female connector KD-8-40-15-S-RST:
For frequency inverters: RST
Suitable for encoder with connector outlet SI8 and SH8, 8 pin, IP40.
Connector (Sub-D 15 pin, 2 rows).
Ready-made shielded connection cable with female cable connector straight and Sub-D connector.
Female connector/ housing / connector housing electrically connected.
Female connector KD-8-40-15-S-SDR:
For controller: Schindler MX
Suitable for encoder with connector outlet SI8 and SH8, 8 pin, IP40.
Connector (Sub-D 15 pin, 2 rows).
Ready-made shielded connection cable with female cable connector straight and Sub-D connector
Female connector/ housing / connector housing electrically connected.
Female connector KD-8-40-15-S-CTF:
For frequency inverters: Control Techniques
Suitable for encoder with connector outlet SI8 and SH8, 8 pin, IP40.
Connector (Sub-D 15 pin, 3 rows).
Ready-made shielded connection cable with female cable connector straight and Sub-D connector
Female connector/ housing / connector housing electrically connected.
Female connector KD-8-40-15-S-KEB:
For frequency inverters: KEB
Suitable for encoder with connector outlet SI8 and SH8, 8 pin, IP40.
connector (Sub-D 15 pin, 3 rows).
Ready-made shielded connection cable with female cable connector straight and Sub-D connector
Female connector/ housing / connector housing electrically connected.
Female connector KD-8-40-15-S-LOH:
For frequency inverters: Flender Loher, type Dynavert L
Suitable for encoder with connector outlet SI8 and SH8, 8 pin, IP40.
connector (Sub-D 15 pin, 3 rows).
Ready-made shielded connection cable with female cable connector straight and Sub-D connector
Female connector/ housing / connector housing electrically connected.
Female connector KD-8-40-15-S-LIF:
For frequency inverters: Liftequip
Suitable for encoder with connector outlet SI8 and SH8, 8 pin, IP40.
Connector (Sub-D 9 pin, 2 rows).
Ready-made shielded connection cable with female cable connector straight and Sub-D connector.
Female connector/ housing / connector housing electrically connected.
Female connector KD-8-40-15-S-ZIL:
For frequency inverters: Ziehl-Abegg
Suitable for encoder with connector outlet SI8 and SH8, 8 pin, IP40.
connector (Sub-D 9 pin, 2 rows).
Ready-made shielded connection cable with female cable connector straight and Sub-D connector.
Female connector/ housing / connector housing electrically connected.
Torque support WDGDS10001
suitable for thru-bore or holllow bore (blind) encodes (all types). Is privieded as standard in the required number with all hollow shaft encoders and end hollow shaft encoders (except 36E and 100G).
Torque support WDGDS10004
Torque support for hollow shaft encoders and end hollow shaft encoders
(all types, except 36E and 100G).
Torque support WDGDS10007
Torque support for hollow shaft encoders and end hollow shaft encoders
(all types, except 36E and 100G).
Torque support WDGDS10008
for hollow shaft encoders and end hollow shaft encoders
(all types, except 36E and 100G).
Torque support WDGDS10009
Torque support for hollow shaft encoders and end hollow shaft encoders
(all types, except 36E and 100G).
Torque support WDGDS10012
for hollow shaft encoders and end hollow shaft encoders
(all types, except 36E and 100G).
Torque support WDGDS10011
for hollow shaft encoders and end hollow shaft encoders
(all types, except 36E and 100G).
Torque support WDGDS10020
Torque support for hollow shaft encoders and end hollow shaft encoders
(all types, except 36E, 40E, WDG 100G).
Shaft adapter WDGWA10M06
for thru-bore and hollow bore (blind) encoder Ø 10 mm
or couplings Ø 10 mm,
thread M6.
Shaft adapter WDGWA10M08
for thru-bore and hollow bore (blind) encoder Ø 10 mm
or couplings Ø 10 mm,
thread M8.
Shaft adapter WDGWA10M10
for thru-bore and hollow bore (blind) encoder Ø 10 mm
or couplings Ø 10 mm,
thread M10.
Shaft adapter WDGWA10M12
for thru-bore and hollow bore (blind) encoder Ø 10 mm
or couplings Ø 10 mm,
thread M12.
STEP file: WDGWA10M12.stp
Shaft adapter WDGWA10M14
for thru-bore and hollow bore (blind) encoder Ø 10 mm
or couplings Ø 10 mm,
thread M14.
Shaft adapter WDGWA10M16
for thru-bore and hollow bore (blind) encoder Ø 10 mm
or couplings Ø 10 mm,
thread M16.
STEP file: WDGWA10M16.stp
Shaft adapter WDGWA10M20
for thru-bore and hollow bore (blind) encoder Ø 10 mm
or couplings Ø 10 mm,
thread M20.
Here you find a list of our distributors worldwide